Fire safety without compromise

When it comes to fire safety, the door is a critical component of a building’s compartmentation strategy. MF Services supplies and installs certified fire-resistant door systems — timber, steel and composite — with ratings from FD30 through to FD120, tested to EN 1634-1 and BS 476.

Whether you’re managing a healthcare facility, school, office or industrial site, our doors are designed to deliver life-safety performance and full compliance — without sacrificing aesthetics or day-to-day functionality.

Certified fire performance

FD30 – FD120

Full range of fire integrity ratings

EN 1634-1

European test standard for door assemblies

ISO 9001 + PSA

Certified and licensed supply and install

Ireland-wide

Nationwide installation and aftercare

empty_605_700

Why our fire doors make a difference

At MF Services, we provide fire-rated door systems for a wide range of commercial, industrial and public buildings — from FD30 models for interior applications through to high-spec FD120 options for critical containment.

Our systems are engineered for Irish safety standards, real-world use, and long-term value:

  • Certified fire ratings (FD30, FD60, FD120) tested to EN 1634-1 and BS 476
  • Timber, composite and steel core options
  • Custom sizes, finishes and vision panels
  • Intumescent seals and compliant ironmongery
  • Expert installation and aftercare across Ireland

What makes a fire door work

The strength of a fire door lies in its construction and how it’s installed. We use tested components and materials that hold up under heat, ensuring the system does what it’s designed to do.

Our fire doors include:

  • Solid cores made from fire-resistant timber, steel or composite materials
  • Intumescent seals that expand in high heat to block smoke and flame
  • Certified hinges, closers and hardware tested as part of the complete door set

Every product we install is backed by documentation to support your fire safety compliance — including test certificates, installation records and post-completion inspection reports.

How often should fire doors be checked?

Under Ireland’s Fire Services Acts 1981 & 2003, the person having control of a building has a legal duty to maintain fire safety equipment — including fire doors — in effective working order. Industry best practice, drawn from BS 8214 and the Fire Door Inspection Scheme (FDIS), is six-monthly inspection for commercial buildings, and quarterly inspection for high-traffic environments such as schools, hospitals and hotels. MF Services offers scheduled inspection contracts to keep buildings compliant across their lifecycle.

Can fire doors be customised to suit the interior design?

Yes. Fire-rated performance is achieved through the door’s construction, seals and hardware — not its finish. That means fire doors can be specified with a wide range of veneers, laminates, colours, glazing options and vision panels, without affecting their rating. Any customisation must be within the parameters of the original test certificate, so the specification is worth confirming with the supplier before manufacture.

How do I know which fire rating I need?

The required fire rating (FD30, FD60, FD90 or FD120) is determined by the building’s fire strategy and Ireland’s Technical Guidance Document B (Fire Safety) under the Building Regulations. In broad terms: FD30 is common for internal partitions and escape routes in low-risk buildings; FD60 is typical for higher-risk compartmentation and stair enclosures; FD120 is required for critical containment such as service risers, plant rooms and separating walls in higher buildings. The fire strategy for your project — usually prepared by a fire consultant — will specify the rating for each opening

Are fire-resistant doors suitable for industrial environments?

Yes. Steel fire doors are designed specifically for industrial applications such as warehouses, factories, logistics facilities and plant rooms — where heavy traffic, mechanical impact and exposure to harsh environments are common. Industrial fire doors can be specified in single-leaf or double-leaf configurations, and can be paired with automatic operation, hold-open devices and access control where operational needs demand it.

What should I consider when choosing commercial fire doors?

Commercial fire doors need to satisfy several requirements simultaneously: the required fire rating (per the fire strategy), compliance with Technical Guidance Document B, acoustic performance where applicable, accessibility under Part M, and integration with the building’s finish and hardware schedule. Well-specified commercial fire doors combine tested performance with visual coherence — so they protect people and comply with regulations without disrupting the design.

Can I hold a fire door open, or must it always be self-closing?

Fire doors must be self-closing under normal circumstances — that’s core to their compartmentation function. However, doors can be held open using an electromagnetic hold-open device that releases automatically on fire alarm activation. These systems are covered by EN 1155, and are commonly specified in care homes, schools and residential entrances where daily use benefits from an open door but fire compartmentation must be maintained. The ECO Schulte FTS III is one such solution.

Where you’ll find our doors

MF Services fire-resistant doors are installed across every major sector in Ireland:

  • Office and commercial buildings — including corporate HQs, co-working spaces and mixed-use developments
  • Retail and hospitality venues — hotels, restaurants, shopping centres and leisure venues
  • Hospitals and healthcare facilities — where compartmentation and hygiene both matter
  • Universities, schools and training centres — where high daily traffic meets fire compliance obligations
  • Industrial units, logistics facilities and data centres — where large-format fire doors are integrated with automatic systems
empty_605_700

Installation and ongoing support

Fire doors must be correctly installed and regularly maintained to remain compliant. That means a Service Level Agreement (SLA) that covers installation, inspection and repair over the door’s lifetime.

  • Expert installation — Our trained team handles everything from frame-fitting to hardware adjustment, so the door system performs exactly as tested.
  • Regular inspections — Scheduled maintenance and compliance inspections keep doors safe over time, especially in high-traffic areas.
  • Warranty and aftercare — Every installation is manufacturer-backed. Repairs and replacement parts available across Ireland.
empty_605_700

In practice: HSE Regional Surgical Hubs

As the HSE rolls out a network of regional surgical hubs to expand day-case capacity, MF Services was appointed by main contractor JJ Rhatigan to supply and install the specialist door and access packages three of these clinical environments depend on — in Cork, Waterford and Limerick.

Fire-rated hygienic sliding doors were specified across all three sites, combining fire compartmentation with hermetic sealing and Code 3 lead lining. At Cork, MF Services delivered the fullest scope — surgical, recovery and circulation areas with fully integrated theatre lockdown — coordinating across different voltages and trades to commission the system alongside the door installation.

Every performance requirement was met: fire rating, lead lining, ventilation and air-tightness, heavy-duty durability. All three hubs delivered on time, on budget and snag-free.

Read the full case study →

Specifying fire doors for your project?

Whether you’re specifying for a new build, refurbishment or ongoing SLA, our team can help you match the right door and rating to each opening. We supply, install and maintain fire-resistant door systems for commercial, healthcare, education and public buildings across Ireland.

Send us your door schedule, drawings or a few lines about the project — we’ll come back with a specification, certificates and indicative pricing.

Need a Quote?

MF Services
Unit 26 Doughcloyne Court Industrial Estate,
Sarsfield Road,
Wilton, Cork, Ireland.

Icon
Sat Nav: Cork N 51° 52.433’ W 8° 30.761’

Speak to an Expert Today

This field is for validation purposes and should be left unchanged.
.......... .......... .......... .......... .......... .......... ..........